External Cleaning and Disinfection Protocol for Hemodialysis Machines

January 24, 2025 uncategorized Wipestar

<p style="text-align: center;"><img src="https://img.wipestar.com/uploads/allimg/20250124/1-250124115301449.jpg" title="Patient helped during hemodialysis session in hospitalpatient helped during dialysis session in hospital" alt="Patient helped during hemodialysis session in hospitalpatient helped during dialysis session in hospital" width="600" height="416"/></p><p><span style="font-size: 18px;">The hemodialysis machine is essential equipment for hemodialysis treatment. As it is used frequently by multiple patients over long periods, it is highly susceptible to contamination from blood, dust, and other contaminants. Particularly during cannulation, patient blood may splash onto the machine, and patients experiencing hypotension may vomit. Various pathogens can colonize the machine, and airborne particles are generated when changing bed linens. Whether contamination is visible or not, the machine must undergo thorough cleaning and disinfection.</span></p><p><br/></p><p><span style="font-size: 18px; color: rgb(0, 112, 192);">Areas prone to blood contamination:&nbsp;</span></p><ul style="list-style-type: disc;"><li><p><span style="font-size: 18px;">Machine surfaces near the cannulation site&nbsp;</span></p></li><li><p><span style="font-size: 18px;">Machine control screen&nbsp;</span></p></li><li><p><span style="font-size: 18px;">Control buttons&nbsp;</span></p></li><li><p><span style="font-size: 18px;">Machine base</span></p></li></ul><p><span style="font-size: 18px; color: rgb(0, 112, 192);">Frequently touched surfaces (high-contact areas):&nbsp;</span></p><ul style="list-style-type: disc;"><li><p><span style="font-size: 18px;">Dialysate connectors&nbsp;</span></p></li><li><p><span style="font-size: 18px;">IV pole&nbsp;</span></p></li><li><p><span style="font-size: 18px;">Machine top</span></p></li></ul><p><br/></p><h2><span style="font-size: 20px;">I. Purpose of Cleaning and Disinfection&nbsp;</span></h2><p><span style="font-size: 18px;">To ensure the external surfaces of hemodialysis machines are free from stains and blood, maintain bacterial counts below national Class III environmental standards, and standardize routine disinfection procedures for relevant personnel.</span></p><p><br/></p><h2><span style="font-size: 20px;">II. Pre-Disinfection Assessment</span></h2><p><span style="font-size: 18px;">Check machine surface contamination for blood, dust, or stains</span></p><p><span style="font-size: 18px;">Verify proper concentration of disinfectant in disposable disinfectant wipes</span></p><p><br/></p><h2><span style="font-size: 20px;">III. Preparation</span></h2><ol style="list-style-type: decimal;"><li><p><span style="font-size: 18px;">Environmental Preparation
Clean and quiet environment with adequate lighting, fresh air, and proper ventilation and air disinfection systems.</span></p></li><li><p><span style="font-size: 18px;">Staff Preparation
Proper attire, hand hygiene, mask, cap, and clean gloves.</span></p></li><li><p><strong><span style="font-size: 18px;">Equipment Preparation
Top tier of treatment cart:</span></strong></p></li></ol><ul style="list-style-type: disc;"><ul style="list-style-type: square;"><li><p><a href="https://www.wipestar.com/products/900.html" target="_self" style="text-decoration: underline;"><span style="font-size: 18px;">Clean cloth</span></a><span style="font-size: 18px;"> or </span><a href="https://www.wipestar.com/products-prewetted-wipes/" target="_self" style="text-decoration: underline;"><span style="font-size: 18px;">disposable disinfectant wipes</span></a></p></li><li><p><span style="font-size: 18px;">500mg/L chlorine-based disinfectant solution</span></p></li><li><p><span style="font-size: 18px;">2000mg/L chlorine-based disinfectant solution (as needed based on contamination level)</span></p></li><li><p><span style="font-size: 18px;">3000-5000ml container</span></p></li><li><p><span style="font-size: 18px;">Box of clean gloves</span></p></li><li><p><span style="font-size: 18px;">Rapid hand sanitizer&nbsp;&nbsp;&nbsp;&nbsp;</span></p></li><li><p><span style="font-size: 18px;">Hemodialysis machine cleaning and disinfection log</span></p></li></ul></ul><p><span style="font-size: 18px;">&nbsp; &nbsp;<strong><span style="font-size: 18px;">Bottom tier of treatment cart:</span></strong></span></p><ul style="list-style-type: disc;"><ul style="list-style-type: square;"><li><p><span style="font-size: 18px;">Contaminated waste container</span></p></li><li><p><span style="font-size: 18px;">Medical waste bin</span></p></li><li><p><span style="font-size: 18px;">General waste bin</span></p></li></ul></ul><p><br/></p><h2><span style="font-size: 20px;">IV. Operating Procedures and Instructions&nbsp;</span></h2><p><span style="font-size: 18px;">Note: Procedures may vary by machine model. Follow specific instructions for each model.
(The following procedure is based on Gambro AK200U)</span></p><p><br/></p><h3><span style="font-size: 18px; color: rgb(0, 112, 192);">Operating Steps:</span></h3><ol style="list-style-type: decimal;"><li><p><span style="font-size: 18px;">After completing hemodialysis treatment, remove tubing</span></p></li><li><p><span style="font-size: 18px;">Assess machine surface contamination and prepare necessary materials</span></p></li><li><p><span style="font-size: 18px;">Wipe with disinfectant cloth:</span></p><p><span style="font-size: 18px;"></span></p><p><span style="font-size: 18px;"></span></p><p style="text-align: center;"><span style="font-size: 16px;"><em>Table 1: Hemodialysis Machine External Disinfection Protocol and Surface Cleaning Procedures</em></span></p><table border="0" cellpadding="0" cellspacing="0" align="center"><colgroup><col width="412" style="width:309.00pt;"/><col width="291" style="width:218.25pt;"/><col width="174" style="width:130.50pt;"/><col width="761" style="width:570.75pt;"/></colgroup><tbody><tr style="height:63.00pt;" class="ue-table-interlace-color-single firstRow"><td class="et3" style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><span style="font-size: 16px;"><strong><span style="font-size: 14px;">Surface Type</span></strong><strong><span style="font-size: 14px;"></span></strong></span></td><td class="et3" style="border-width: 1px; border-style: solid; border-color: gainsboro; word-break: break-all;" align="center" valign="middle"><strong><span style="font-size: 14px;">Disinfectant&nbsp;</span></strong></td><td class="et3" style="border-width: 1px; border-style: solid; border-color: gainsboro; word-break: break-all;" align="center" valign="middle"><strong><span style="font-size: 14px;">Sequence</span></strong></td><td class="et3" style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><strong><span style="font-size: 14px;">Procedure</span></strong></td></tr><tr style="height:63.00pt;" class="ue-table-interlace-color-double"><td style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><span style="font-size: 14px;">Regular Surfaces (No visible contamination)</span></td><td style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><span style="font-size: 14px;">500mg/L</span></td><td style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><span style="font-size: 14px;">First Surface</span></td><td class="et4" style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><span style="font-size: 14px;">Screen and control panel<br/>Right side of machine</span></td></tr><tr style="height:63.00pt;" class="ue-table-interlace-color-single"><td style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><br/></td><td style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><br/></td><td style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><span style="font-size: 14px;">Second Surface</span></td><td class="et4" style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><span style="font-size: 14px;">IV pole (top to bottom)<br/>Machine top surface (&quot;M&quot; pattern)<br/>Left side and left bichamber holder</span></td></tr><tr style="height:63.00pt;" class="ue-table-interlace-color-double"><td style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><br/></td><td style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><br/></td><td style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><span style="font-size: 14px;">Third Surface</span></td><td class="et4" style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><span style="font-size: 14px;">Front (blood pump, pressure sensors, substitution pump, safety valve, heparin pump holder)<br/>Dialysate bypass connector and tubing</span></td></tr><tr style="height:63.00pt;" class="ue-table-interlace-color-single"><td style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><br/></td><td style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><br/></td><td style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><span style="font-size: 14px;">Fourth Surface</span></td><td class="et4" style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><span style="font-size: 14px;">Solution A and B ports and tubing<br/>Dialyzer clamp<br/>Machine base</span></td></tr><tr style="height:63.00pt;" class="ue-table-interlace-color-double"><td style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><span style="font-size: 14px;">Blood-Contaminated Surfaces</span></td><td style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><span style="font-size: 14px;">2000mg/L then 500mg/L</span></td><td style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><span style="font-size: 14px;">Two-Step Process</span></td><td class="et4" style="border-width: 1px; border-style: solid; border-color: gainsboro; word-break: break-all;" align="center" valign="middle"><p><span style="font-size: 14px;">1. Clean with 2000mg/L wipes<br/>2. Disinfect with 500mg/L wipes</span></p></td></tr><tr style="height:63.00pt;" class="ue-table-interlace-color-single"><td style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><span style="font-size: 14px;">Infection Zone Surfaces (HBV, HCV, syphilis, HIV)</span></td><td style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><span style="font-size: 14px;">2000mg/L</span></td><td style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><span style="font-size: 14px;">Single-Step Process</span></td><td style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><span style="font-size: 14px;">Clean with 2000mg/L chlorine-based disposable wipes</span></td></tr><tr style="height:106.00pt;" class="ue-table-interlace-color-double"><td style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><span style="font-size: 14px;">Clean-up Procedures</span></td><td style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><span style="font-size: 14px;">500mg/L</span></td><td style="border-width: 1px; border-style: solid; border-color: gainsboro;" align="center" valign="middle"><span style="font-size: 14px;">Post-Cleaning Steps</span></td><td class="et4" style="border-width: 1px; border-style: solid; border-color: gainsboro; word-break: break-all;" align="center" valign="middle"><span style="font-size: 14px;">1. Place used cloths in contaminated waste container<br/>2. Wash thoroughly<br/>3. Soak in 500mg/L chlorine solution (30 minutes)<br/>4. Rinse and dry for reuse<br/>5. Organize supplies and sort waste<br/>6. Record time and operator&#39;s name</span></td></tr></tbody></table><p><br/></p></li><li><p style="text-wrap-mode: wrap;"><span style="font-size: 18px;">Disposable disinfectant wipes are recommended, following the same wiping method and sequence</span></p></li><li><p style="text-wrap-mode: wrap;"><span style="font-size: 18px;">For infection zones (including HBV, HCV, syphilis, HIV positive patients), use 2000mg/L chlorine-based disposable disinfectant wipes</span></p></li><li><p style="text-wrap-mode: wrap;"><span style="font-size: 18px;">Clean-up:</span></p></li><ol style="list-style-type: lower-alpha;"><li><p style="text-wrap-mode: wrap;"><span style="font-size: 18px;">Place used cloths in contaminated waste container, wash thoroughly, soak in 500mg/L chlorine solution for 30 minutes, rinse clean, dry for reuse</span></p></li><li><p style="text-wrap-mode: wrap;"><span style="font-size: 18px;">Organize supplies, sort waste appropriately</span></p></li><li><p style="text-wrap-mode: wrap;"><span style="font-size: 18px;">Record disinfection time and operator&#39;s full name</span></p></li></ol><p style="text-wrap-mode: wrap;"><span style="font-size: 18px;"></span></p><p style="text-wrap-mode: wrap;"><span style="font-size: 18px;"></span></p><p style="text-wrap-mode: wrap;"><span style="font-size: 18px;"></span></p><p style="text-wrap-mode: wrap;"><span style="font-size: 18px;"></span></p></ol><h3><span style="font-size: 18px; color: rgb(0, 112, 192);"></span></h3><h3 style="text-wrap-mode: wrap;"><span style="font-size: 18px; color: rgb(0, 112, 192);"><br/></span></h3><h3 style="text-wrap-mode: wrap;"><span style="font-size: 18px; color: rgb(0, 112, 192);">Operating&nbsp;</span><span style="color: rgb(0, 112, 192); font-size: 18px;">Key Points:</span></h3><ul style="list-style-type: disc;"><li><p><span style="font-size: 18px;">Have 2000mg/L chlorine solution ready based on contamination level</span></p></li><li><p><span style="font-size: 18px;">Fold cloth in four, following &quot;M&quot; pattern in same direction, use different surfaces for different areas, avoid overlap</span></p></li><li><p><span style="font-size: 18px;">Use one cloth per machine per person</span></p></li><li><p><span style="font-size: 18px;">Pay attention to knobs, corners, and buttons</span></p></li><li><p><span style="font-size: 18px;">Open blood pump cover to clean inside of pump door and rotor</span></p></li><li><p><span style="font-size: 18px;">Clean machine back weekly with 500mg/L chlorine solution</span></p></li><li><p><span style="font-size: 18px;">Mark opening date on disposable wipes to monitor evaporation</span></p></li><li><p><span style="font-size: 18px;">For display screens, after using 2000mg/L wipes, wait briefly then clean with clean gauze to reduce corrosion</span></p></li><li><p><span style="font-size: 18px;">Use dedicated cloths for different zones</span></p></li></ul><p><br/></p><h2><span style="font-size: 20px;">V. Important Notes</span></h2><ul style="list-style-type: disc;"><li><p><span style="font-size: 18px;">Cleaning principles: One person, one machine, one cloth; clean from top to bottom, left to right, clean to contaminated areas.</span></p></li><li><p><span style="font-size: 18px;">Two critical cleaning times:&nbsp;Immediately after establishing extracorporeal circulation. After removing tubing and dialyzer.</span></p></li><li><p><span style="font-size: 18px;">Use different surfaces of cloth/wipes, avoid reuse, prevent hand contact with machine surfaces.</span></p></li><li><p><span style="font-size: 18px;">Clean hard-to-reach areas (blood pump, pressure sensors, safety valve) weekly using soft brush or cotton swabs.</span></p></li><li><p><span style="font-size: 18px;">Use hand sanitizer and clean gloves between machines.</span></p></li><li><p><span style="font-size: 18px;">After each use, clean machine surface with disposable, microfiber disinfectant wipes that have adequate friction and moisture content.</span></p></li></ul><p><span style="font-size: 18px;"></span></p><p><span style="font-size: 18px;"></span></p><h2 style="text-wrap-mode: wrap;"><span style="font-size: 20px;"><br/></span></h2><h2 style="text-wrap-mode: wrap;"><span style="font-size: 20px;">About Us</span></h2><p style="text-wrap-mode: wrap;"><span style="font-size: 18px;">Wipestar specializes in manufacturing high-quality&nbsp;</span><a href="https://www.wipestar.com/products/" target="_self"><span style="font-size: 18px; text-decoration: underline;">lint-free wiping cloths</span></a><span style="font-size: 18px;">&nbsp;specifically designed for professional medical equipment cleaning. Our product line includes both dry and pre-saturated options, engineered to meet the stringent cleanliness requirements of medical devices and critical healthcare environments.</span></p><p><br/></p><p><br/></p>

Tags:No tag

RELATED RESOURCES

Previous : Polyester vs. Microfiber: A Comprehensiv... Next:Detailed Cleaning, Disinfection and Main...

Related Products

Contact Details

Room 101, Building 1, Angeer Factory, No.4, Hetian Road, Shatian Community, Kengzi Street, Pingshan District, Shenzhen, Guangdong, P.R. China 518122

info@wipestar.com

+86-755-89616775

+86-755-89616773

Related Products

RELATED RESOURCES

The two exhibitions concluded | WIPE S...

The two exhibitions concluded | WIPE S...

 March 26-28, 2025 The global semiconductor and el […]

More

How to choose a reel clean room wiper?...

How to choose a reel clean room wiper?...

Scroll dust-free cloth selection guide and technical specifications1. Scientific basis for material ...

More

Phone Icon
×
Please dial our contact phone number
+86-755-89616773
Make a Call