Language

News

How to Use Particle Counters for Gas Sampling

February 26, 2025 uncategorized Wipestar

<p style="text-align: center;"><img src="https://img.wipestar.com/uploads/allimg/20250226/1-25022609194B26.webp" title="High Tech Empty Scientific Cleanroom with high tech machines" alt="High Tech Empty Scientific Cleanroom with high tech machines" width="600" height="399"/></p><p><span style="font-size: 16px;">Compressed gases are common in cleanrooms but also carry contamination risks. Properly using particle counters with high-pressure diffusers can detect contamination in compressed air.</span></p><p><span style="font-size: 16px;"><br/></span></p><h2><span style="font-size: 20px;">I. Using Particle Counters for Cleanroom Gas Sampling</span></h2><p><span style="font-size: 16px;">GMP requirements mandate testing compressed gases in cleanroom applications. This testing is critical because ISO 5 cleanroom product process areas require strict contamination control. Compressed gases can cause particulate contamination if not properly tested, affecting the quality and safety of sterile products. Testing gas pipelines can mitigate another source of increased cleanroom contamination, which may also affect cleanroom classification.</span></p><p><span style="font-size: 16px;">ISO 14644-1 specifies the required air cleanliness for different cleanroom levels, based on air samples collected at given locations. Results are compared with tables for validating cleanroom ISO classes. For example, ISO 14644-1 requires the following limits for air sampling per cubic meter in cleanrooms:</span></p><p style="text-align: center;"><span style="font-size: 16px;"><img src="https://img.wipestar.com/uploads/allimg/20250226/1-2502260ZZ3547.webp" title="Figure 1: ISO 14644-1:2015 Air Cleanliness by Particle Classification" alt="Figure 1: ISO 14644-1:2015 Air Cleanliness by Particle Classification" width="800" height="365"/></span></p><p style="text-align: center;"><em><span style="font-size: 14px;">Figure 1: ISO 14644-1:2015 Air Cleanliness by Particle Classification</span></em></p><p><span style="font-size: 16px;"><br/></span></p><p><span style="font-size: 16px;">In the pharmaceutical industry, sterile processing primarily occurs in ISO 5 level cleanrooms. Therefore, particle concentration should be below the test size limits. If 0.5 μm and 1.0 μm particles are tested using a particle counter, the limits for each size would be 3,520 and 832 respectively per location.</span></p><p><span style="font-size: 16px;">The number of locations is based on a lookup table (outlined in ISO 14644-1:2015) and the size of the cleanroom. If all sample locations are below the particle size per cubic meter sample, the cleanroom will be classified as an ISO 5 cleanroom.</span></p><p><span style="font-size: 16px;">If gas pipelines are contaminated, this will result in further gas contamination of the room, potentially failing to meet ISO 5 requirements. This can lead to product safety and quality risks. ISO 8573 is the standard to follow when testing gas pipelines. ISO 8573-1:2010 outlines the maximum number of particles per cubic meter, the same concept as ISO 14644-1:2015.</span></p><p><strong><span style="font-size: 16px;">ISO 8573 – Part 4:</span></strong></p><ol style="list-style-type: decimal;"><li><p><span style="font-size: 16px;">Provides methods for compressed air sampling.</span></p></li><li><p><span style="font-size: 16px;">Guidelines for selecting appropriate measuring equipment to determine particle size and concentration.</span></p></li><li><p><span style="font-size: 16px;">Establishes a minimum sampling volume of 1000L (1m³).</span></p></li><li><p><span style="font-size: 16px;">Uses optical particle counters for testing particle sizes ≥0.1 to ≤10 μm.</span></p></li></ol><p><br/></p><h2><span style="font-size: 20px;">II. ISO 8573-1:2010 Solid Particle Table</span></h2><p><span style="font-size: 16px;">For example, a Class 5 cleanroom must have fewer than 100,000 particles per cubic meter sample for particle sizes 0.5&lt;d≤5.0µm. For Class 4, this value is ≤10,000. Class 3 should be ≤1,000, Class 2 ≤100, and Class 1 will be ≤10.</span></p><p style="text-align: center;"><span style="font-size: 16px;"><img src="https://img.wipestar.com/uploads/allimg/20250226/1-2502260Z9324V.webp" title="Figure 2: ISO 8537-1:2010 Classifications" alt="Figure 2: ISO 8537-1:2010 Classifications" width="800" height="568"/></span></p><p style="text-align: center;"><em><span style="font-size: 14px;">Figure 2: ISO 8537-1:2010 Classifications</span></em></p><p><span style="font-size: 16px;"><br/></span></p><p><span style="font-size: 16px;">Using an Optical Particle Counter (ISO 8573-4):</span></p><ul style="list-style-type: disc;"><li><p><span style="font-size: 16px;">Isokinetic sampling should be maintained (using a high-pressure diffuser if particle diameter &gt;1μm)</span></p></li><li><p><span style="font-size: 16px;">OPC particle size range 0.1μm to 5μm</span></p></li><li><p><span style="font-size: 16px;">Sample reports include:</span></p></li><li><p><span style="font-size: 16px;">Sterile or non-sterile declaration</span></p></li><li><p><span style="font-size: 16px;">Sampling date</span></p></li><li><p><span style="font-size: 16px;">Measurement date</span></p></li><li><p><span style="font-size: 16px;">Location</span></p></li></ul><p><span style="font-size: 16px;"><br/></span></p><h2><span style="font-size: 20px;">III. Selecting the Correct HPD</span></h2><p><span style="font-size: 16px;">To sample compressed gas, the particle counter needs an accessory called a High Pressure Diffuser (HPD). The HPD connects the particle counter and the compressed gas line, and diffuses the gas entering the particle counter sample inlet. If high-pressure gas enters the particle counter inlet without an HPD, the sensors inside the particle counter may be damaged, and test results will be inaccurate.</span></p><p style="text-align: center;"><span style="font-size: 16px;"><img src="https://img.wipestar.com/uploads/allimg/20250226/1-2502260Z951312.webp" title="Figure 3: (1) Exhaust Return Flow HPD" alt="Figure 3: (1) Exhaust Return Flow HPD" width="800" height="250"/></span></p><p style="text-align: center;"><em><span style="font-size: 14px;">Figure 3: <em style="font-size: 14px; text-align: center; text-wrap-mode: wrap;">Port Exhaust HPD</em></span></em></p><p style="text-align: center;"><span style="font-size: 16px;"><img src="https://img.wipestar.com/uploads/allimg/20250226/1-250226091020933.png" title="Figure 4: Port Exhaust HPD" alt="Figure 4: Port Exhaust HPD" width="800" height="256"/></span></p><p style="text-align: center;"><span style="font-size: 14px;"><em>Figure 4: <em style="text-align: center; text-wrap-mode: wrap;"><span style="font-size: 14px;">Exhaust Return Flow HPD</span></em></em></span></p><p><span style="font-size: 14px;"><em><br/></em></span></p><h2><span style="font-size: 20px;">IV. Setting HPD Flow Rate</span></h2><p><span style="font-size: 16px;">When using an HPD, it is critical to match the flow rate of the particle counter used for testing compressed gas. The diagram below outlines the correct HPD adapter adjustments based on the inlet pressure of the compressed gas to be sampled, in order to maintain the ideal particle flow.</span></p><p style="text-align: center;"><span style="font-size: 16px;"><img src="https://img.wipestar.com/uploads/allimg/20250226/1-250226091120220.webp" title="Figure 5: Isokinetic High Pressure Diffuser Adjustment Diagram" alt="Figure 5: Isokinetic High Pressure Diffuser Adjustment Diagram" width="800" height="480"/></span></p><p style="text-align: center;"><em><span style="font-size: 16px;">Figure 5: Isokinetic High Pressure Diffuser Adjustment Diagram</span></em></p><p><span style="font-size: 16px;"><br/></span></p><h2><span style="font-size: 20px;"></span></h2><h2 style="text-wrap-mode: wrap;"><span style="font-size: 20px;">V.&nbsp;Setting Up the Particle Counter and HPD for Compressed Air Sampling</span></h2><p><span style="font-size: 16px;">The HPD connects the compressed gas line and particle counter according to the diagram below. Ensure adapter fittings are secure, gas lines have no leaks, and air flow direction is correct.</span></p><p style="text-align: center;"><span style="font-size: 16px;"><img src="https://img.wipestar.com/uploads/allimg/20250226/1-25022609113G35.webp" title="Figure 6: Compressed Gas to Remote Particle Counter Flow" alt="Figure 6: Compressed Gas to Remote Particle Counter Flow" width="800" height="527"/></span></p><p style="text-align: center;"><span style="font-size: 14px;"><em>Figure 6: Compressed Gas to Remote Particle Counter Flow</em></span></p><p><span style="font-size: 16px;"><br/></span></p><h2><span style="font-size: 20px;">Maintaining Your Cleanroom Environment with Wipestar</span></h2><p><span style="font-size: 16px;">While proper gas sampling is essential for cleanroom compliance, maintaining overall cleanliness is equally important. Wipestar&#39;s premium cleanroom wipes are specifically designed to complement your contamination control strategy. Our low-particle, lint-free wipes are ideal for ISO-classified environments, including the critical ISO 5 areas discussed in this article.</span></p><p><a href="https://www.wipestar.com/products/" target="_self" style="text-decoration: underline;"><span style="font-size: 16px;">Wipestar wipes</span></a><span style="font-size: 16px;"> feature:</span></p><ul style="list-style-type: disc;"><li><p><span style="font-size: 16px;">Ultra-low particulate generation to maintain ISO classification standards</span></p></li><li><p><span style="font-size: 16px;">Excellent solvent compatibility for effective cleaning around sampling equipment</span></p></li><li><p><span style="font-size: 16px;">Available in multiple grades to match your specific cleanroom requirements</span></p></li><li><p><span style="font-size: 16px;">Sterile options for the most demanding applications</span></p></li></ul><p><span style="font-size: 16px;">Protect your compressed gas sampling results by ensuring your cleanroom surfaces remain contaminant-free with Wipestar&#39;s trusted cleanroom wipes. Learn more about our complete range of contamination control solutions </span><a href="https://www.wipestar.com/resources/polyester-cleanroom-wipers.html" target="_self" style="text-decoration: underline; font-size: 16px;"><span style="font-size: 16px;">HERE</span></a><span style="font-size: 16px;">.</span></p><p><br/></p>

Tags:No tag

RELATED RESOURCES

Previous : A Comprehensive Guide to Aircraft De-ici... Next:Four Methods for Cleaning Stainless Stee...

Related Products

Contact Details

Room 101, Building 1, Angeer Factory, No.4, Hetian Road, Shatian Community, Kengzi Street, Pingshan District, Shenzhen, Guangdong, P.R. China 518122

info@wipestar.com

+86-755-89616775

+86-755-89616773

Related Products

RELATED RESOURCES

The two exhibitions concluded | WIPE S...

The two exhibitions concluded | WIPE S...

 March 26-28, 2025 The global semiconductor and el […]

More

How to choose a reel clean room wiper?...

How to choose a reel clean room wiper?...

Scroll dust-free cloth selection guide and technical specifications1. Scientific basis for material ...

More

Phone Icon
×
Please dial our contact phone number
+86-755-89616773
Make a Call